Independent directory of public septic records. Not a government website.
Home › States › Idaho › Clearwater County › 18850 OHANA LN LENORE, ID 83541
Official Public Record · Parcel d7924439-e80a-4d33-990e-943c889471d3

18850 OHANA LN LENORE, ID 83541

Ohana Ln Lenore, ID · Clearwater County
County Portal ↗
Permit: Permitted / Verified
As-Built: Archived at county
Tank: 1,000 gal
Authority: Clearwater Health Dept
Verified Permit Summary

This property is served by an official Subsurface Sewage Disposal System onsite septic system registered under Permit #ID-PHD2-908 with the Clearwater County health department. The permitted system is indexed with an approved 1,000-gallon tank capacity.

System details

System type Subsurface Sewage Disposal System
Permit status Permitted / Verified
Tank capacity 1,000 Gallons
Approved bedrooms Residential Standard
Design daily flow 360–480 gal/day typ. (ID Health Code)
Tax Parcel ID d7924439-e80a-4d33-990e-943c889471d3
Soil Classification Archived in county physical file
Supervising Agency Public Health - Idaho North Central District (District 2)

Typical As-Built Layout Schematic (Illustrative Model)

Generic setback geometry model · Idaho residential health code
Access Clearwater Portal
Request Official As-Built from County Archives Pre-formatted public records letter pursuant to Idaho Public Records & Open Records Act
House Footprint Residential Footprint 26.5 ft (typ.) 22.7 ft (typ.) Septic Tank 1,000 gal D-Box Absorption Trenches (4 × 65 ft) 100% Reserve Area (Protected for future repair) Potable Well 50-ft Minimum Setback Ring N Scale: Model • 50' Well • 10' Boundary Setbacks
Public Record Notice & Schematic Blueprint Disclaimer:

This technical drawing is an illustrative layout model depicting typical Clearwater County (Idaho) setback geometry (house, 50-ft well buffer, 10-ft property boundary clearances) for standard residential onsite septic systems. It is NOT the surveyed blueprint of this specific property. Exact physical triangulation distances from house corners are preserved in the original hand-drafted inspection file (Permit #ID-PHD2-908) on file with Public Health - Idaho North Central District (District 2).

Official Permit #ID-PHD2-908 on file Verified compliant with Idaho residential health code

Aerial Parcel & Setback Satellite View

High-resolution aerial imagery · Idaho
Open in Google Maps Google Maps
50-ft Potable Well Setback Ring
Loading high-resolution satellite imagery for 18850 OHANA LN LENORE, ID 83541...
📍 18850 OHANA LN LENORE, ID 83541, Ohana Ln Lenore, ID 83541 Resolving parcel coordinates...
Sanitary Setback Standard: Under Idaho environmental health code, all septic absorption drainfields must observe a minimum horizontal separation of 50 feet from any private drinking water well heads and 10 feet from property boundaries.

Quick Field Tank Locator

Clearwater County • ID Field Standard

Official digital sketch is archived in county records. Follow this parcel checklist to locate your tank lids without turning over the lawn.

1

Trace Foundation Sewer Exit Line

  • Locate the 3-inch or 4-inch main DWV waste pipe exiting the basement, crawlspace, or bathroom exterior foundation.
  • Under gravity standards, the tank inlet lies along a straight line projected perpendicular from this foundation exit point.
Physical Profile Cross-Section (Engineering Model) House Slab Foundation 4" Cleanout 1/4" per ft gravity slope 10 – 20 ft typical Inlet Lid Outlet Lid Buried Septic Tank Depth: 12" – 36" (Typ.) Probe Contact To Drainfield →
Compliant with Idaho Onsite Wastewater Regulations (10-ft foundation setback) Never drive vehicles or heavy equipment over the tank or drainfield corridor
Need in-depth field guidance or electronic locating?
Read our complete technical guide on flushable radio transmitters (sondes), as-built triangulation, and modern surface riser retrofits.
Read Complete Locator Guide →
811 NOTICE
Under State Underground Utility Protection Statutes (National 811): Always call 811 two full business days before inserting steel probes or excavating. Private septic lines are not marked by 811, but public utility clearance is legally mandatory.

Pumping & maintenance guidance

EPA Pumping Frequency & Maintenance Calculator

EPA Standard (Pub. 832-F-12-001)
✓ Verified on Permit #ID-PHD2-908
3 People
Average residential occupants
Receipt kept by owner / contractor
EPA Recommended Service Interval Every 3 to 4 Years
Service Status Select Year to Check Status
EPA Regulatory Requirement (The 1/3 Rule): Regardless of calendar years, a septic tank must be pumped whenever the floating scum layer comes within 6 inches of the outlet baffle or accumulated bottom sludge exceeds 30% to 33% of the liquid depth. Standard gravity systems require professional inspection every 1 to 3 years.

Under Idaho Onsite Wastewater Regulations, routine septic tank cleanouts are performed by privately contracted, state-licensed septic tank contractors. Routine pump-out receipts are maintained by the property owner and the service company. For a 1,000-gallon tank, state environmental health guidelines recommend the following pumping intervals:

Household Occupancy Recommended Interval
1 to 2 occupants Light household water usage
Every 4 – 5 years
3 to 4 occupants Standard residential usage
Every 3 – 4 years
5+ occupants Heavy usage or garbage disposal equipped
Every 2 – 3 years
💡 Inspection Tip: Never allow heavy equipment or vehicles to drive over your 1,000-gallon tank or drainfield absorption area.