Independent directory of public septic records. Not a government website.
Home › States › North Carolina › Wake County › Parcel PIN 0790155193
Official Public Record · Parcel 0790155193

Parcel PIN 0790155193

Raleigh, NC · Wake County
County Portal ↗
Permit: Approved
As-Built: Archived at county
Tank: Standard Res.
Authority: Wake Health Dept
Verified Permit Summary

This property is served by an official Type II - Class A - Stone onsite septic system registered under Permit #B026671 with the Wake County health department. System specifications and engineering clearances are indexed in the official county environmental health registry.

System details

System type Type II - Class A - Stone
Permit status Approved
Tank capacity Standard Residential (Unspecified in index)
Approved bedrooms Residential Standard
Design daily flow 360–480 gal/day typ. (NC 15A-18E)
Tax Parcel ID 0790155193
Soil Classification Drain Type: Stone
Supervising Agency Wake County Department of Environmental Services - Water Quality Division

Typical As-Built Layout Schematic (Illustrative Model)

Generic setback geometry model · North Carolina residential health code
Access Official Permit
Request Official As-Built from County Archives Pre-formatted public records letter pursuant to North Carolina General Statutes Chapter 132 (Public Records Law)
House Footprint Residential Footprint 31.6 ft (typ.) 24.7 ft (typ.) Septic Tank 1,000 gal (Typ.) D-Box Absorption Trenches (4 × 65 ft) 100% Reserve Area (Protected for future repair) Potable Well 100-ft Minimum Setback Ring N Scale: Model • 100' Well • 10' Boundary Setbacks
Public Record Notice & Schematic Blueprint Disclaimer:

This technical drawing is an illustrative layout model depicting typical Wake County (North Carolina) setback geometry (house, 100-ft well buffer, 10-ft property boundary clearances) for standard residential onsite septic systems. It is NOT the surveyed blueprint of this specific property. Exact physical triangulation distances from house corners are preserved in the original hand-drafted inspection file (Permit #B026671) on file with Wake County Department of Environmental Services - Water Quality Division.

Official Permit #B026671 on file Verified compliant with North Carolina residential health code

Aerial Parcel & Setback Satellite View

High-resolution aerial imagery · North Carolina
Open in Google Maps Google Maps
100-ft Potable Well Setback Ring
Loading high-resolution satellite imagery for Parcel PIN 0790155193...
πŸ“ Parcel PIN 0790155193, Raleigh, NC Resolving parcel coordinates...
Sanitary Setback Standard: Under North Carolina environmental health code, all septic absorption drainfields must observe a minimum horizontal separation of 100 feet from any private drinking water well heads and 10 feet from property boundaries.

Quick Field Tank Locator

Wake County • NC Field Standard

Official digital sketch is archived in county records. Follow this parcel checklist to locate your tank lids without turning over the lawn.

1

Trace Foundation Sewer Exit Line

  • Locate the 3-inch or 4-inch main DWV waste pipe exiting the basement, crawlspace, or bathroom exterior foundation.
  • Under gravity standards, the tank inlet lies along a straight line projected perpendicular from this foundation exit point.
Physical Profile Cross-Section (Engineering Model) House Slab Foundation 4" Cleanout 1/4" per ft gravity slope 10 – 20 ft typical Inlet Lid Outlet Lid Buried Septic Tank Depth: 12" – 36" (Typ.) Probe Contact To Drainfield →
Compliant with North Carolina 15A NCAC 18E Onsite Water Protection (10-ft foundation setback) Never drive vehicles or heavy equipment over the tank or drainfield corridor
Need in-depth field guidance or electronic locating?
Read our complete technical guide on flushable radio transmitters (sondes), as-built triangulation, and modern surface riser retrofits.
Read Complete Locator Guide →
811 NOTICE
Under North Carolina General Statutes Β§ 87-115 (NC 811): Always call 811 two full business days before inserting steel probes or excavating. Private septic lines are not marked by 811, but public utility clearance is legally mandatory.

Pumping & maintenance guidance

EPA Pumping Frequency & Maintenance Calculator

EPA Standard (Pub. 832-F-12-001)
Unspecified in filing β€” adjust if different
3 People
Average residential occupants
Receipt kept by owner / contractor
EPA Recommended Service Interval Every 3 to 4 Years
Service Status Select Year to Check Status
EPA Regulatory Requirement (The 1/3 Rule): Regardless of calendar years, a septic tank must be pumped whenever the floating scum layer comes within 6 inches of the outlet baffle or accumulated bottom sludge exceeds 30% to 33% of the liquid depth. Standard gravity systems require professional inspection every 1 to 3 years.

Under North Carolina 15A NCAC 18E (Onsite Water Protection), routine septic tank cleanouts are performed by privately contracted, state-licensed septic tank contractors. Routine pump-out receipts are maintained by the property owner and the service company. For a standard residential tank, state environmental health guidelines recommend the following pumping intervals:

Household Occupancy Recommended Interval
1 to 2 occupants Light household water usage
Every 4 – 5 years
3 to 4 occupants Standard residential usage
Every 3 – 4 years
5+ occupants Heavy usage or garbage disposal equipped
Every 2 – 3 years
πŸ’‘ Inspection Tip: Never allow heavy equipment or vehicles to drive over your septic tank or drainfield absorption area.